IR-thermometer IR 1200-50D
Battery
Temperature sensor thermocouple type-K (measuring range -20 to +250 °C)
Table stand
USB-cable (Mini-USB ->USB)
Software CD
Transport case
Operating instructions

The infrared thermometer enables contract-free measurement of surface-temperatures. It determines temperature
according to the radiated infrared energy that is emitted by every object. Contact-free measurement makes it ideal
for dangerous, difcult to access, moving or live objects. It cannot measure through transparent media such as
glass, plastics, water, etc.. Instead, the surface temperature is measured at all times. The temperature measuring
range goes from -50 to +1200 °C. A double laser target device facilitates determination of the measuring range.
Additionally, a contact measurement with a thermal element sensor type K is possible in the measuring range from
-50 to +1370 °C, depending on the sensor used.
The IR-thermometer as such must not come directly into contact with the measured temperature. A sufcient safety
distance and the admissible ambience conditions must be complied with under all circumstances.
Diagnostic application in the medical area is not admissible.
The degree of emissions can be adjusted to the present surface property of the measured object. A table of common
materials is integrated.
The IR thermometer additionally has an internal measuring storage for up to 30 measured values. These values
may be read at the graphics display of the meter or via the installed USB interface.
A 9 V-block battery serves voltage supply. No energy supply other than the one indicated must be used.
This product complies with the statutory national and European requirements. For safety and approval reasons
(CE), the entire product must not be changed or converted and the housing must not be opened except for ex-
change of batteries.
Using the product for any other purposes than those described above may damage the product or cause a danger
of injury.
Read the operating instructions precisely and keep them. Only pass the product on to any third parties together with
the operating instructions.
Always observe the safety information included in these operating instructions.