Temperature
Range Resolution: Accuracy
-30 to 0 °C 0.1 °C ± 4 °C
1 to +230 °C 0.1 °C ±2% or ±2 °C
Response time < 1 s
Emissivity 0,95
Measuring optics 4:1 (Distance:measuring spot diameter)
Diode test
Test voltage approx. 1.5 V
Test current approx. 1 mA
Resolution: 0.001 V
Accuracy ±(10% + 5)
Overload protection: 600 V
Acoustic continuity tester <100 Ω continuous sound, test voltage approx 0.5 V,
overload protection 600 V