VOLTCRAFT VC-110 Instrucciones de operaciones Pagina 50

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 49
50
Direct current (DC)
Range Resolution: Accuracy
200 µA 0.1 µA
2000 µA 1 µA
±(1,5% + 5)
20 mA 0.01 mA
200 mA 0.1 mA
2 A 0.001 A
±(2,5% + 5)
10 A 0.01 A
Other Features Overload protection: Fuse; 600 V;
Measuring time limit > 5 A: max. 30 s with
15 min break
Alternating current (AC)
Range Resolution: Accuracy
200 µA 0.1 µA
2000 µA 1 µA
±(2% + 5)
20 mA 0.01 mA
200 mA 0.1 mA
2 A 0.001 A
±(3% + 5)
10 A 0.01 A
Other Features Overload protection: Fuse; 600 V;
Measuring time limit > 5 A: max. 30 s with
15 min break
Resistance
Range Resolution: Accuracy
200 Ω 0.1 Ω ±(1% + 5)
2 kΩ 0.001 kΩ
20 kΩ 0.01 kΩ ±(1% + 2)
200 kΩ 0.1 kΩ
2 MΩ 0.001 MΩ
±(2,5% + 8)
20 MΩ 0.01 MΩ
Other Features Overload protection 600V; Measuring voltage:
approx. 0.45 V