f) Test mode
Press and hold the “MODE” button (> 1 second) and then select the test mode by pressing
the “MODE” button again..
Press “CURRENT” to select the charging current (200, 500, 700mA). The discharging
current (100, 250, 350mA) is half of the selected discharging current.
Press “DISPLAY” button to scroll through different displays, charging current (mA), battery
voltage (V), accumulated capacities (mAh) or time elapsed (hh:mm).
Stage in charging
mode
Current (mA) Voltage (V)
Capacity
(mAh/Ah)
Time (hh:mm)*
During charging Charging current
Instantaneous
battery voltage
“--- mAh”
Charging time
elapsed
During discharging
Discharging
current
“--- mAh”
Discharging
time elapsed
During second
charging
Charging current
Capacity
determined in
discharging
Second
charging time
elapsed
During trickle
charging
Trickle charging
current
Discharging
time elapsed
g) Tickle charging
After the rechargeable battery is fully charged in any of the operating modes, the charger
will send impulse form of current to the rechargeable batteries to maintain the fully charged
level. This mode is automatically launched after rechargeable batteries are fully charged
and kept at the charging unit. The “Full” icon will be displayed on the display.
* The timer will be resumed and counted from 00:00 again after the time elapsed is longer
than 20 hours. (For example, 1:45 will be shown after the battery has been refreshed for
21 hr and 45 min.)